Part Number Hot Search : 
CLT5170 SB2040 R0100 03001 R0100 SB2040 XCX15DNH M630Q
Product Description
Full Text Search
 

To Download MAX-703-0512 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com 700, 750 watts multiple output max-700 max-750 msc-750 featuring: over 4 watts/in 3 power density 80% overall efficiency vmebus and multibus ii system compatibility meets international safety agency requirements all outputs fully regulated 1% high peak current for motor starting ac automatic line selection option specify the appropriate max-700 or max-750 and get new design freedom for your high-end computer products. use a system air cooled max-700, an optional self-cooled max-700 or standard self- cooled max-750. you can reduce your product size by replacing an 11?x 8?x 5 unit with a 58% smaller max-750. build in power supply redundancy by replacing one ordinary switcher with two max-700s in the same space. model pwr output #1 output #2 output #3 output #4 MAX-703-0512 700 +5v @ 100a +12v @ 12/20a pk -12v @ 10a max-704-1205 700 +5v @ 100a +12v @ 12/20a pk -12v @ 10a 5.2v @ 2a max-753-0512 750 +5v @ 120a +12v @ 12/20a pk -12v @ 10a max-754-1205 750 +5v @ 120a +12v @ 12/20a pk -12v @ 10a 5.2v @ 2a max-754-1212 750 +5v @ 120a +12v @ 12/20a pk -12v @ 10a 12v @ 2a max-754-1224 750 +5v @ 120a +12v @ 12/20a pk -12v @ 10a +24v @ 2a max-754-1252 750 +5v @ 120a +12v @ 12/20a pk -5.2v @ 10a 12v @ 2a standard max series model pwr output #1 output #2 output #3 msc-753-0512 750 +5v @ 120a +12v @ 20/27a pk -12v @ 6a mass storage msc series option f
condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com 700, 750 watts 13.5? 5 x 2.6 max-700, 750 msc-750 function 115 vac 230 vac connector input select short open 0.250 male faston tb1- line line 1 tb1- neutral line 2 tb1- safety ground safety ground ac input function location notes connector output #1 terminal marked +v main output terminal marked com rtn (common) output #2 tb2-3 tb2-4 rtn (common) output #3 tb2-5 tb2-4 rtn (common) output #4* tb2-1 (+) (if provided) tb2-2 (-) *rtn connected to common only if output is polarized in product selection chart dc output barrier strip #6-32 screws 3/8?centers bus bars #1/4-20 screws barrier strip # 6-32 screws 3/8?centers function location notes connector j1-1(+ s) output #1 sense j1-2 (?s) output #1 sense rtn ac power fail, or j1-3 (pf) reference to j1-2 dc power good* inhibit j1-4 (ih) short to j1-2 *optional function status and control amp mta type #640456-4 pin header (locking) remote sense option ?? dc power good: provides a ttl ??open collector when output #1 is above 4.6 v nominal. not available if option ??is selected. option ?? ac power fail: provides ttl ??5 ms before output voltage goes out of regulation band upon loss of ac power. vmebus compatible, provides 48 ma sink current capability. not available if option ??is selected. consult factory for other available options. specifications: all models input ac input: 90-132 vac/180-264 vac, 47 to 63 hz. user selectable. see option ??for automatic line selection. internally fused for 15 a. inrush: cold start ac current is less than 90 a at 115 vac and 30 a at 230 vac. limited by thermistor. holdup time: 16 ms minimum after removal of power, at nominal line, full load. efficiency: 80% typical. brownout protection: holds regulation to 85 vac or 170 vac. output adjustability: user adjustable ?% minimum. line & load reg: ?% over ac input range and 0 to 100% load change. output #1 requires minimum load of 10%. ripple & noise: less than 1% p-p or 100 mv, whichever is greater. remote sense (output #1) : compensates for 250 mv total line drop. open sense lead protection. temperature coefficient: 0.02% per degree c. stability: 0.1% over 8 hours after 30 minutes warm-up. transient response (output #1) : output voltage returns to within 1% in less than 500 ? for a 50% load change. peak transient does not exceed 5%. overload protection: all outputs are protected against overload and short circuit. automatic recovery upon removal of fault. overvoltage protection (output #1) : protects load against power supply induced overvoltage. trip point is factory set so that output voltage cannot exceed 136% of nominal. remote inhibit: contact closure to the negative sense line drops output power to nominal zero. reverse voltage: protected against reverse voltage up to supply current rating. environmental thermal protection: shuts down power supply if overheated. automatic recovery. temperature range: 0 to 50? at full ratings. derate to half power at 70?. safety agencies: most models are approved to ul1950; csa 22.2 #234; iec 950 and t?v en60950, class 1 selv., ce 72/23/eec/93/68eec (low voltage directive). conducted rfi: meets fcc part 15, subpart j, class a; en55022 class b; cispr 22 class b. cooling: 30 cfm required to achieve full ratings. output isolation: isolated from ground 50 vdc. options: option ?? ac auto-range: automatically selects proper ac line voltage range to enable power operation at either 115 or 230 vac without user intervention. option ?? fan/cover assembly: cover with integral ball-bearing fan provides proper cooling to achieve full ratings at 50? ambient temperature. max-700 6.1 lbs - 2.8 kgs dimensions: inches millimeters max-700, msc-750 with option f, max-750, 6.4 lbs - 2.9 kgs (l) (n) ( )


▲Up To Search▲   

 
Price & Availability of MAX-703-0512

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X